NUR 2790 Discussion Artifact vs Dysrhythmia
NUR 2790 Discussion Artifact vs Dysrhythmia
NUR 2790 Discussion Artifact vs Dysrhythmia
Describe the role of each component of the ECG in the heart’s contraction: the P wave, the PR interval, the QRS complex, the ST segment, the T wave, and the QT interval. What is the difference between artifact and dysrhythmia? How can you reduce artifacts? What are som
e situations that can occur if artifact is not reduced or eliminated?
You are working in the Telemetry Unit. The nurse “watching” the monitors is reading a magazine. She constantly turns off an alarm that looks a lot like Ventricular Fibrillation. She tells you that it is not a dysrhythmia, it is just artifact. What do you think about her actions? What is the worst case scenario in this situation? What would you do?
Unlike ischemic changes which are present in specific ECG leads depending on the site of an anatomic lesion, ventricular arrhythmias must be evident in all ECG leads. Given that our patient had normal sinus rhythm in two leads, VT could be safely excluded from the differential diagnosis of the patient’s unusual findings. While it can sometimes be a challenge to correctly identify a patient’s rhythm, Huang et al have proposed a tested ECG algorithm to differentiate tremor induced pseudo-VT and true VT.1 According to the algorithm, the presence of any of the three characteristic signs will exclude true VT as the diagnosis. Our patient’s tracing has the characteristic “sinus sign”, wherein sinus rhythm is observed in a frontal or limb lead as demonstrated in leads III and V1 (Figure 2). The explanation is that if the upper limbs are not affected by tremor, sinus rhythm will be seen in the corresponding leads. The “notch” sign, also present in our patient is seen where a notch is present on a QRS complex and represents the length of the sinus cycle (Figure 2). The final sign described in the algorithm is the “spike sign” which are small spikes found within QRS complexes. According to the algorithm, the absence of all three signs will lead to the diagnosis of true VT. This algorithm was tested in a hospital and was able to correctly diagnose 97.3% of cases. The application of Huang’s algorithm to our patient’s telemetry strips is one clinical tool that can be used to differentiate arrhythmia from artifact in the case of questionable electrocardiographic features.
In the absence of clinical correlation, our patient’s rhythm strip may present a challenge because of how closely it mimics VT. The wide QRS complexes suggest VT and the twisting nature of the QRS complexes around an isoelectric line may be interpreted as polymorphic. Possible explanations for the pseudo-VT seen in this case include tremor, patient movement or disruption in lead placement, all common scenarios in the inpatient setting. Knight et al examined patients who were misdiagnosed with VT and consequently underwent unnecessary interventions ranging from diagnostic coronary angiogram to permanent pacemaker or defibrillator implantation in addition to medical therapy.2 They also found that misdiagnosis occurred by cardiologists, emergency medicine physicians, and house officers, highlighting the importance of recognition of artifact and true arrhythmia across all specialties.3 The investigators followed up these findings with a survey of internists, cardiologists, and electrophysiologists who were shown an ECG tracing of artifact and asked to make an interpretation. Strikingly, 94% of internists, 58% of cardiologists, and 38% of electrophysiologists misdiagnosed the ECG as VT. Of these, 53% of cardiologists and 88% of electrophysiologists recommended further invasive management or treatment. The misdiagnosis of artifact is likely more common than it is reported and has both economic and medical implications.
Tremor is the most common cause of electrocardiographic artifact and Parkinsonian tremor mimicking VT leading to unnecessary intervention has been reported in the literature.4,5 Other etiologies of tremor as well as patient agitation may cause interference on a telemetry monitor altering the rhythm displayed. ECG lead misplacement is another common issue faced in both the inpatient and outpatient settings.6 This is in part due to the variations in lead placement, time constraints in emergencies, and lack of operator experience.7,8 The increasing use of mobile phones particularly in the hospital can also create ECG interference and mimic VT.9 Rapid physical examination and identification of any potential causes of artifact should be part of the initial bedside evaluation.
Conclusion
ECG findings of a patient are part of a broader clinical picture and should not be viewed in isolation. They also demonstrate the utility of the ECG algorithm developed by Huang et al which can be used to differentiate pseudo-VT from true VT in an uncertain circumstance. Our case further highlights the importance of examining all ECG leads for discrepancies in rhythm before subjecting a patient to potentially harmful and unnecessary interventions. It is of utmost importance to clinically assess a patient for symptoms suggestive of hemodynamic instability. The use of these considerations can result in fewer unnecessary interventions for a patient and less distress to the medical team.